UL 506
01 / 01
Commercial · Toroidal Magnetics
Power Supply Transformers (Bare toroid).
Model 636.220
Step-up transformer, 220V single secondary
UL 506CSA C22.2 No.66UL 1411
Rated Power
360
VA · standard
No-Load V
233
volts nominal
Quotes & availability:[email protected]1-888-286-7643
Technical Overview
Engineered to the stringent safety standards of UL 506 and international equivalents.
Step-up transformer, 220V single secondary
Part of the 117V Single Primary (60Hz), Single primary configuration, rated at 360 VA.
- 3-agency safety recognition
- Agency file UL E-161696 / C-UL E-161696 / UL E-98086
- Commercial-grade construction
- 4 mounting options
- Characterised no-load voltage
At a glance
- Part Number
- 636.220
- Series
- 117V Single Primary (60Hz)
- Rated Power
- 360 VA
- Primary
- 117 V
- Secondary
- 220 V
- Grade
- Commercial
- Frequency
- Domestic, 117V / 60 Hz
Specifications
Part-level electrical & physical data
| Part Number | 636.220 |
|---|---|
| Series | 117V Single Primary (60Hz) |
| Rated Power | 360 VA |
| Primary Voltage | 117 V |
| Primary Configuration | Single |
| Secondary Voltage | 220 V |
| Secondary Current (Series) | 1.64 A |
| No-Load Voltage | 233 V |
| Market / Frequency | Domestic, 117V / 60 Hz |
| Form Factor | Bare toroid |
| Grade | Commercial |
| Agency File | UL E-161696 / C-UL E-161696 / UL E-98086 |
Agency Recognition
Full agency recognition, ready to certify.
Listed under agency file UL E-161696 / C-UL E-161696 / UL E-98086.
- UL 506
- CSA C22.2 No.66
- UL 1411
Resources
Everything you need to specify or design-in
Product datasheet
Full electrical, mechanical and agency data.
DownloadMounting options
- Poly 100/32
- L-300
- Omega #4
- Washer 90
Specify a variant
Need a custom winding or enclosure? Send your requirements.
Open the formTalk to Engineering
Talk to a magnetics designer. Not a sales rep.
Our engineering team reviews every specification for 636.220 directly. Quotes typically turn around within 48 hours.